Location: | Goa, India |
Project Name: | Deltin Suites Hotel and Casino |
Installation Date: | 2nd September 2019 |
Project Size (System Capacity): | 75 KLD High Strength |
Customer: | Delta Corporation Ltd. |
Designer: | BioWater Treatment Systems LLP (Vadodara, India) |
Manufacturer: | BioMicrobics Inc. |
Equipment:
- 2 x SaniTEE® 1618 in 40 KL Settling Tank
- 1 x AMS 2.0 in 42 KL Equalisation Tank
- 1 x MyFAST® 2.0 in 104 KL Treatment Tank
- 1 x BMS 2.0 in 38 KL Tank
- Sodium Hypochlorite Dosing
- Pressure Sand Filter
Background
The Deltin Suites is a 106 room 5-Star hotel with a casino and 2 restaurants. It is located in the state of Goa, where tourism is the major industry. The hotel had an MBBR based 25 KLD treatment system which was grossly undersized, took up a lot of space, needed operators in 3 shifts and was unable to treat the wastewater. The result was a terrible odour which was offensive to guests as well as the surrounding residents who raised strong objection with the Pollution Control Board. Furthermore, Deltin was spending a handsome amount of money each month to have the sewage carted away in tankers every 2-3 days.
Challenges
Space:
Every square foot of the property was utilised for the structures, access roads, parking, utilities, pool, etc. The only available space was a small garden between the old STP and the reception structure which was a repurposed heritage structure.
Running Hotel:
Being a running hotel, the old STP had to be kept running until the new one was commissioned.
Aesthetics:
Since the only available location was right next to the reception, aesthetics was important.
Sewage Characteristics:
Parameters | Influent | Effluent from FAST® | Effluent after PSF-ACF |
BOD5 | <350 ppm | <30 ppm | <10 |
COD | <500 ppm | <80 ppm | <50 |
TSS | <300 ppm | <30 ppm | <10 |
pH | 6.5 – 8.0 | 6.5 – 8.0 | 6.5 – 8.0 |
Oil & Grease | <40 ppm | <5 ppm | Nil |
(BOD = Biological Oxygen Demand; COD = Chemical Oxygen Demand; TSS = Total Suspended Solids)
Treated Water use: Toilet Flushing
Solution:
BioWater Treatment Systems LLP designed a 75 KLD system to cope with the higher load and to squeeze in between the old heritage structure and the tanks of the old treatment system using the MyFAST® 2.0 with AMS® and BMS® options. Once the MyFAST® 2.0 and AMS® were installed in new tanks, the old system was decommissioned. The pump room was recommissioned into a drivers’ waiting room, the old tanks were reused for the BMS® system after internal modifications, a lawn was laid on the old STP tanks and a parking space was created on the new tanks.
System:
See System Layout Chart
Result:
BioWater was able to replace the old STP with a new one with 3 times the capacity using less space and no full-time operator. Space was freed up for parking and a drivers’ waiting room while the overall aesthetics of the area was improved.
Pictures: See attached presentation. Installation pictures after Layout.
Website: https://www.deltin.com/deltin-suites-hotel/
Google Location: https://maps.app.goo.gl/XagPgQJ4iaPLfGSLA